Details
Duct Connected - High Static Pressure - FDU
Enhanced installation workability
Quier, Lightweight and Compact
With the FDU71, the noise level is only 37dB (low), weight is only 40kg and height is only 297mm. In addition 600mm Drain Pump is mounted in FDU71/100/125/140VD. The indoor unit is completely hidden in the ceilling, so this is suitable for spaces with classy interior decoration.![]() |
||||||
Model Name | *FDU71VNXVD | *FDU100VNXVD | *FDU140VNXVD | *FDU100VSXVD | *FDU140VSXVD | |
Indoor Model | FDU71VD | FDU100VD | FDU140VD | FDU100VD | FDU140VD | |
Outdoor Model | FDC71VNX | FDC100VNX | FDC140VNX | FDC100VSX | FDC140VSX | |
Power Source (Ph/V/Hz) : | 1 Phase, 220-240V, 50Hz | 3 Phase, 380-415V, 50Hz | ||||
Nominal Cooling Capacity (Min-Max (kW)) (ISO-T1(JIS)) : | 7.1 (3.2-8.0) | 10.0 (4.0-11.2) | 14.0 (5.0-16.0) | 10.0 (4.0-11.2) | 14.0 (5.0-16.0) | |
Nominal Heating Capacity (Min-Max (kW)) (ISO-T1(JIS)) : | 8.0 (3.6-90.0) | 11.2 (4.0-12.5) | 16.0 (4.0-18.0) | 11.2 (4.0-16.0) | 16.0 (4.0-20.0) | |
Power Consumption Coolling/Heating (kW) : | 2.15/2.15 | 2.78/2.90 | 4.20/4.30 | 2.78/2.90 | 4.20/4.30 | |
COP Coolling/Heating: | 3.30/3.72 | 3.60/3.86 | 3.33/3.72 | 3.60/3.86 | 3.33/3.72 | |
Energy Label Coolling/Heating : | A/A | |||||
Inrush current (Max. running current (A)) : | 5(17) | 5(25) | 5(30) | 5(16) | 5(19) | |
External Static Pressure (Pa) : | Standard:60, Max:130 | |||||
Range of usage Ref.piping length (m) : | 50 | 100 | ||||
Range of usage Vertical height difference : - O/U is higher (m) : O/U is lower (m) : |
30 15 |
|||||
Operating Temperature range : - Coolling (O/U) : Heating (O/U) : |
-15-43ˉ² -20-20 |
|||||
Indoor Model | ||||||
Sound pressure level (dB(A)) : | Hi:41 Lo:27 | Hi:42 Lo:37 | Hi:43 Lo:38 | Hi:42 Lo:37 | Hi:43 Lo:38 | |
Air Flow (CMM) : | Hi:20 Lo:17 | Hi:34 Lo:27 | Hi:42 Lo:33.5 | Hi:34 Lo:27 | Hi:42 Lo:33.5 | |
Exterior dimensions (mm) : | 297 x 850 x 850 | 350 x 1370 x 650 | ||||
Net weight (kg) : | 40 | 63 | ||||
Air filter, Q'ty : | Procure Locally | |||||
Remote control (option) : | Wired: RC-EX1A, RCH-E3 Wireless: RCN-KIT3E | |||||
Outdoor Model | ||||||
Sound pressure level (dB(A)) : | Coolling:51 Heating:48 | Coolling:48 Heating:50 | Coolling:49 Heating:52 | Coolling:48 Heating:50 | Coolling:49 Heating:52 | |
Sound power level (dB(A)) : | 66 | 70 | 72 | 70 | 72 | |
Air Flow (CMM) : | Coolling:60 Heating:50 | Coolling:100 Heating:100 | ||||
Exterior dimensions (mm) : | 750 x 880(+88) x 340 | 1300 x 970 x 370 | ||||
Net weight (kg) : | 60 | 105 | ||||
Type of compressor : | Rotary | |||||
Ref. Amount Precharged (Kg(m)) : | 2.95(30) | 4.5(30) | ||||
Ref. piping Size (Liquid/Gas (ø)) : | 9.52/15.88 |
![]() |
||||||
Model Name | *FDU100VNVD | *FDU140VNVD | *FDU100VSVD | *FDU140VSVD | *FDU200VSVF | *FDU250VSVF |
Indoor Model | FDU100VD | FDU140VD | FDU100VD | FDU140VD | FDU200VF | FDU250VF |
Outdoor Model | FDC100VN | FDC140VN | FDC100VS | FDC140VS | FDC200VS | FDC250VS |
Power Source (Ph/V/Hz) : | 1 Phase, 220-240V, 50Hz | 3 Phase, 380-415V, 50Hz | 3 Phase, 380-415V, 50Hz, 3 Phase, 380V, 60Hz | |||
Nominal Cooling Capacity (Min-Max (kW)) (ISO-T1(JIS)) : | 10.0 (4.0-11.2) | 14.0 (5.0-14.5) | 10.0 (4.0-11.2) | 14.0 (5.0-14.5) | 20.0 (7.0-22.4) | 25.0 (10.0-28.0) |
Nominal Heating Capacity (Min-Max (kW)) (ISO-T1(JIS)) : | 11.2 (4.0-12.5) | 16.0 (4.0-16.5) | 11.2 (4.0-12.5) | 16.0 (4.0-16.5) | 22.4 (7.6-25.0) | 28.0 (9.5-31.5) |
Power Consumption Coolling/Heating (kW) : | 2.88/2.99 | 4.95/4.43 | 2.88/2.99 | 4.95/4.43 | 50Hz:6.59/6.08, 60Hz:6.58/5.84 | 50Hz:9.91/8.50, 60Hz:10.21/8.22 |
COP Coolling/Heating: | 3.47/3.75 | 2.83/3.61 | 3.47/3.75 | 2.83/3.61 | 50Hz:3.03/3.68, 60Hz:3.04/3.84 | 50Hz:2.25/3.29, 60Hz:2.45/3.41 |
Energy Label Coolling/Heating : | A/A | C/A | A/A | C/A | B/A | 50Hz:E/C, 60Hz:E/B |
Inrush current (Max. running current (A)) : | 5(25) | 5(28) | 5(16) | 5(19) | 5(24) | 5(27) |
External Static Pressure ⁺² (Pa) : | Standard:50, Max:130 | Standard:100, Max:200 | ||||
Range of usage Ref.piping length (m) : | 50 | 70 | ||||
Range of usage Vertical height difference : - O/U is higher (m) : O/U is lower (m) : |
30 15 |
|||||
Operating Temperature range of Coolling (O/U) : | -15-43⁺³; | |||||
Operating Temperature range of Heating (O/U) : | -20-20 | -15-20 | ||||
Indoor Model | ||||||
Sound pressure level (dB(A)) : | Hi:42 Lo:37 | Hi:43 Lo:38 | Hi:42 Lo:37 | Hi:43 Lo:38 | 51 | 52 |
Air Flow (CMM) : | Hi:34 Lo:27 | Hi:42 Lo:33.5 | Hi:34 Lo:27 | Hi:42 Lo:33.5 | 50Hz:51, 60Hz:60 | 50Hz:68, 60Hz:80 |
Exterior dimensions (mm) : | 350 x 1370 x 650 | 360 x 1570 x 830 | ||||
Net weight (kg) : | 63 | 92 | ||||
Air filter, Q'ty : | Procure Locally | |||||
Remote control (option) : | Wired: RC-EX1A, RC-E5 Wireless: RCN-KIT3E | |||||
Outdoor Model | ||||||
Sound pressure level (dB(A)) : | 49 | 51 | 49 | 51 | 57 | Coolling:57 Heating:58 |
Sound power level (dB(A)) : | 70 | 73 | 70 | 73 | 74 | |
Air Flow (CMM) : | Coolling:75 Heating:73 | Coolling:150 Heating:145 | ||||
Exterior dimensions (mm) : | 845 x 970 x 370 | 1300 x 970 x 370 | 1505 x 970 x 370 | |||
Net weight (kg) : | 81 | 83 | 122 | 140 | ||
Type of compressor : | Rotary | Scroll | ||||
Ref. Amount Precharged (Kg(m)) : | 3.8(30) | 5.4(30) | 7.2(30) | |||
Ref. piping Size (Liquid/Gas (ø)) : | 9.52/15.88 | 9.52/25.4 | 12.7/25.4 |